Angiotensin II is angiotensin I without its C-terminal dipeptide, His-Leu: the first eight of its ten residues.
Sequences side by side
Angiotensin II is a continuous stretch of Angiotensin I: 8 residues in common, aligned below by Angiotensin I's numbering. In each column the upper residue is Angiotensin I's and the lower is Angiotensin II's. Positions outside the shorter sequence are dimmed.
Both have the same termini: free amine and free acid.
Calculated properties
| Property | Angiotensin I | Angiotensin II | Difference (Angiotensin II − Angiotensin I) |
|---|---|---|---|
| Residues | 10 | 8 | −2 |
| Molecular formula | C62H89N17O14 | C50H71N13O12 | |
| Monoisotopic mass (Da) | 1,295.6775 | 1,045.5345 | −250.1430 |
| Average mass (g/mol) | 1,296.50 | 1,046.20 | −250.30 |
| Net charge at pH 7 | 0.5 | 0.2 | −0.2 |
| Isoelectric point | 7.71 | 7.54 | −0.16 |
| Hydropathy (GRAVY) | -0.20 | -0.33 | −0.12 |
| ε280 (M−1 cm−1) | 1,490 | 1,490 |
Telling them apart by mass spectrometry
The monoisotopic masses differ by 250.1430 Da, which any routine mass spectrometer resolves.
| Ion | Angiotensin I | Angiotensin II |
|---|---|---|
| [M+H]+ | 1,296.6848 | 1,046.5418 |
| [M+2H]2+ | 648.8460 | 523.7745 |
| [M+3H]3+ | 432.8998 | 349.5188 |
Telling them apart by HPLC
Angiotensin I is the more hydrophobic by the Kyte–Doolittle average (a difference of 0.12), so in reversed-phase HPLC it would usually be expected to elute later. Retention depends on the whole molecule and on the method, so the order is confirmed by running both, or by mass spectrometry of each peak.
Analytical variants each can form
The sequence-specific variants from each entry. A variant only one of them can form is a quick way to tell which is which, and a reminder of what to look for in each.
| Variant | Mass change | Angiotensin I | Angiotensin II |
|---|
Full details, with isotope patterns and fragment ions, are on each entry: Angiotensin I and Angiotensin II. Both are compared with the rest of their family on the family page.
Sources & Further Reading
- Prohaska T, Irrgeher J, Benefield J, Böhlke JK, Chesson LA, Coplen TB, et al. Standard atomic weights of the elements 2021 (IUPAC Technical Report). Pure and Applied Chemistry 2022;94(5):573–600. doi:10.1515/pac-2019-0603
- Wang M, Huang WJ, Kondev FG, Audi G, Naimi S. The AME 2020 atomic mass evaluation (II). Tables, graphs and references. Chinese Physics C 2021;45(3):030003. doi:10.1088/1674-1137/abddaf
- Rice P, Longden I, Bleasby A. EMBOSS: the European Molecular Biology Open Software Suite. Trends in Genetics 2000;16(6):276–277. doi:10.1016/S0168-9525(00)02024-2
- Pace CN, Vajdos F, Fee L, Grimsley G, Gray T. How to measure and predict the molar absorption coefficient of a protein. Protein Science 1995;4(11):2411–2423. doi:10.1002/pro.5560041120
- Kyte J, Doolittle RF. A simple method for displaying the hydropathic character of a protein. Journal of Molecular Biology 1982;157(1):105–132. doi:10.1016/0022-2836(82)90515-0
- Meija J, Coplen TB, Berglund M, Brand WA, De Bièvre P, Gröning M, et al. Isotopic compositions of the elements 2013 (IUPAC Technical Report). Pure and Applied Chemistry 2016;88(3):293–306. doi:10.1515/pac-2015-0503
- Roepstorff P, Fohlman J. Letter to the editors: proposal for a common nomenclature for sequence ions in mass spectra of peptides. Biomedical Mass Spectrometry 1984;11(11):601. doi:10.1002/bms.1200111109
- Biemann K. Contributions of mass spectrometry to peptide and protein structure. Biomedical and Environmental Mass Spectrometry 1988;16(1–12):99–111. doi:10.1002/bms.1200160119
- Geiger T, Clarke S. Deamidation, isomerization, and racemization at asparaginyl and aspartyl residues in peptides. Succinimide-linked reactions that contribute to protein degradation. Journal of Biological Chemistry 1987;262(2):785–794. doi:10.1016/S0021-9258(19)75855-4
- Manning MC, Chou DK, Murphy BM, Payne RW, Katayama DS. Stability of protein pharmaceuticals: an update. Pharmaceutical Research 2010;27(4):544–575. doi:10.1007/s11095-009-0045-6
- D'Hondt M, Bracke N, Taevernier L, Gevaert B, Verbeke F, Wynendaele E, et al. Related impurities in peptide medicines. Journal of Pharmaceutical and Biomedical Analysis 2014;101:2–30. doi:10.1016/j.jpba.2014.06.012
See also
- Angiotensin I
- Angiotensin II
- Sermorelin and CJC-1295 (no DAC) compared — comparison
- Sermorelin and Tesamorelin compared — comparison
- GHRP-6 and GHRP-2 compared — comparison
- GHRP-6 and Hexarelin compared — comparison
- Leu-enkephalin and Met-enkephalin compared — comparison
- Thymosin β4 and TB-500 compared — comparison
- α-MSH and KPV compared — comparison
- Amyloid-β (1–42) and Amyloid-β (1–40) compared — comparison
- Oxytocin and Arg-vasopressin compared — comparison
- Endomorphin-1 and Endomorphin-2 compared — comparison
- Angiotensin II and Angiotensin III compared — comparison
- Kallidin and Bradykinin compared — comparison
- All peptides: the property table
Cite this page
Text
Cosmic Peptides. (2026, October 25). Angiotensin I and Angiotensin II compared. Cosmic Peptides Research Library. Retrieved October 26, 2026, from https://cosmicpeptides.com/research/peptides/compare/angiotensin-i-vs-angiotensin-ii
BibTeX
@misc{cosmicpeptides_research_peptides_compare_angiotensin_i_vs_angiotensin_ii,
author = {{Cosmic Peptides}},
title = {Angiotensin I and Angiotensin II compared},
howpublished = {Cosmic Peptides Research Library},
year = {2026},
month = oct,
url = {https://cosmicpeptides.com/research/peptides/compare/angiotensin-i-vs-angiotensin-ii},
urldate = {2026-10-26},
note = {Last reviewed 2026-10-25}
} RIS
TY - ELEC AU - Cosmic Peptides TI - Angiotensin I and Angiotensin II compared T2 - Cosmic Peptides Research Library PB - Cosmic Peptides PY - 2026 DA - 2026/10/25 UR - https://cosmicpeptides.com/research/peptides/compare/angiotensin-i-vs-angiotensin-ii Y2 - 2026/10/26 LA - en ER -
Cite the date the page was last reviewed, October 25, 2026, as its version. Reference managers such as Zotero can save this page directly.
Changes to this page
- Published Structural comparisons of related peptides
Eight pairs of related peptides side by side: the sequences aligned, calculated properties, and how mass spectrometry and HPLC tell them apart.
Changes of substance are listed here; wording changes are not. Every correction is also on the corrections log.
For in vitro laboratory research only. Not for human or veterinary use. This library describes chemistry, analytical methods and published laboratory research; it gives no guidance on use in people or animals.